Choosing the right lighting in a warehouse is crucial for operating costs, comfort, and safety. Traditional light sources are increasingly being replaced by modern linear LED lamps, which offer the lowest energy consumption and longest lifespan. It's worth analyzing which solution is more cost-effective in the long run, taking into account installation and operating costs, as well as environmental impact.

Why is choosing the right lighting in a warehouse crucial?

Properly selected light sources enable precise performance of duties, minimizing the risk of errors and accidents. In warehouses, where employees frequently operate machinery, transport goods, pack, and pick orders, ensuring adequate light intensity and uniform distribution is crucial. In many cases, other important factors, such as glare reduction, flicker-free lighting, and color temperature, are also important. Insufficient light can lead to eye fatigue, reduced concentration, and decreased work efficiency, while excessive brightness can cause glare, discomfort, and irritation.

Energy-intensive fluorescent tubes generate high electricity bills, and the need to frequently replace bulbs or tubes increases maintenance costs. For large warehouses, these costs can constitute a significant portion of the operating budget. Choosing an energy-efficient solution, such as LED lighting, can reduce energy consumption and infrastructure maintenance costs. 

T8 LED linear lamps in the warehouse instead of traditional fluorescent lamps, fluorescent lamps or LED fluorescent lamps - a comparison of factors influencing costs

Traditional warehouse lighting was a common solution in warehouses and logistics centers for years. The use of glass tubes, fluorescent lamps, mercury vapor lamps, sodium vapor lamps, and halogen lamps provided sufficient brightness but were associated with high energy consumption. Furthermore, these lamps contain a small amount of mercury, posing a risk to employee health and the risk of mercury entering stored products. Although this type of lighting is still found in many warehouses, rising energy costs and the development of modern technologies make it a completely uneconomic solution. LED fluorescent lamps, light sources that require fixtures, are also being gradually phased out. 

Thanks linear LED lamps It's possible to achieve higher brightness levels with significantly lower energy consumption, which directly reduces warehouse maintenance costs. Therefore, when choosing warehouse lamps, it's worth considering a parameter such as luminous efficacy. The higher the luminous efficacy, the lower your electricity bills.

These savings result not only from lower power consumption but also from the longer lifespan of these light sources, which reduces the frequency of lamp replacements and maintenance costs. Below is a table comparing different types of light sources.

An additional advantage of LEDs is the possibility of using intelligent control systems that adjust light intensity to current conditions and demand. Motion sensors and automatic regulation of lighting intensity allow for even greater optimization of energy consumption, eliminating losses resulting from unnecessary lighting of empty rooms or empty warehouse areas. 

Light fixtures often last several years longer than the fluorescent tube itself, but this is also a vulnerable element of the lighting system. Furthermore, linear lamps are much more compact and sealed, preventing dirt from entering the interior. Light fixtures often lose their seal after just two years.

Parameterbulbfluorescent lampfluorescent lampLED fluorescent lampLED linear lamp
Luminous efficiency5-20 lm/W20-40 lm/W40-70 lm/Wapprox. 80-110 lm/W120-180 lm/W
Vitalityapprox. 1000 hours2000-3000 hours8000-12000 hoursusually 25000 h50000 hours
Mounting systemE27 threadT8 and T5 fixture, G13 mountT8 and T5 fixture, G13 mountT8 fixturehandles, cable ties, other
Dangerheating, glasscontain mercury, glasscontain mercury, glassglass is often used–
Tightnessdepends on the settingdepends on the settingdepends on the settingdepends on the settingIP65 or higher, 
Power range40-100 W18-36 W9-36 W6-18 W12-100 W (mostly 18W, 36W)
Pricehighlowlowlowmedium/high

It is worth taking into account that the short lifespan of the lamps also means additional labor costs, and the more time per year the lights are on in the facility, the faster the modernization of the lighting system will pay for itself.

All this translates into savings of 50-90% of electricity, and over the entire lifetime of the linear lamp even up to 98% of savings (taking into account lamp replacements related to short life, workload for lamp replacement and maintenance).

All these light sources can be powered by 230V, so the installation of linear LED lamps does not require any significant modifications to the installation. 

LED linear lamps vs traditional lighting and LED linear fluorescent lamps?

The quality of lighting affects visual comfort and well-being and must comply with occupational health and safety regulations.

The most important factors to consider when planning the right lighting system:

Illuminance on the floor surface and on the work surface

According to the standard, the person responsible for the lighting design of a given room must ensure average illuminance, taking into account various factors: failure rate, flux drop factor, pollution, and wall color. This ensures the highest standards of safety and comfort for employees. Below are tables with appropriate illuminance levels for various surfaces:

Room

Type of surface

Illumination level

Corridors/communication areas

floor

100 lx

Stairs

floor

150 lx

Washing, mixing, packaging products

working

200 lx

Cutting and sorting fruit

working

100 lx

Feed preparation, dairies

working

300 lx

Warehouse

floor

100 lx

Cold stores

floor

300 lx

Production hall

working

200 – 1500 lx*

Workshop

working

300 – 750 lx*

Sheds, garages

floor

50 lx

Laboratories

working

500 lx

Dressing room

floor

200 lx

Bathroom

floor

200 lx

Cafeteria

working

200 lx

Office

working

500 lx

Conference rooms

working

500 lx

Packing zone

working

300 lx

Loading ramp

floor

150 lx

Pavement

floor

40 lx

Parking

floor

75 lx

Emergency

floor

1-5 lx

* – depending on the work performed in a given position

The standard working surface is set at 80 cm above the floor, but when making detailed analyses, the actual workstations are assumed, taking into account the height of the equipment used.
If you are interested in a comprehensive lighting design for selected rooms or the entire facility – please contact usWe have specialised in industrial lighting design for years and will deliver high-quality lamps in line with your suggestions and the PN-EN 12464-1:2022-01 standard.

Illumination uniformity

It's practically impossible to design lighting with perfect uniformity. However, certain proportions must be maintained to ensure safety and comfort. In most cases, more lamps with lower power are used, but this isn't always possible. In our designs, we also ensure that the uniformity of the light intensity doesn't negatively impact visual conditions, especially when moving quickly across the hall.

Light color

There are usually two options for lamps for work surfaces and communication areas – neutral (4000K) or cool (5000-6500K). Light color has a different impact on work performance. Neutral is very good for long hours of creative work, provides high visual comfort, and allows for good color perception. Cool colors stimulate activity, have a positive effect on concentration and productivity, and are most often used in workstations. Daily exposure to blue light for many hours can, after several years, lead to reduced vision quality.

Flickering and stroboscopic effect

A crucial factor in production and workshop environments! Rotating machinery such as electric motors, generators, lathes, and others should not be illuminated by fluorescent or low-quality LED lamps. This creates the risk of a stroboscopic effect. If the lamp's flicker frequency and the machine's rotation frequency are identical or many times greater, the visual effect will be identical to that of a stationary machine! This visual experience is so compelling that the brain ignores even the noise of a running engine. This is a very dangerous situation that can lead to bodily harm!

The glare effect

Glare effects (momentary blindness) can also cause problems with work safety and efficiency. Care should be taken to ensure that no lamp at the workstation produces excessively intense light in the worker's field of vision. This depends on the arrangement and angle of light distribution of each lamp, its length, and its power. 

Summary

A well-designed, flicker-free lighting system ensures even light distribution, which can cause discomfort and headaches with some traditional sources. Stable lighting reduces the risk of errors and improves workstation ergonomics. An additional advantage is the lack of excessive heat emission, which is particularly important in warehouses with limited ventilation or in facilities requiring controlled temperatures. Thanks to these advantages, LED technology contributes to improved warehouse operational efficiency and employee health and safety. Good lighting reduces the risk of accidents!

New LED lighting also offers a quick return on investment. If you're replacing fluorescent lamps with LED linear lamps This investment can pay for itself in just 1.5 years after installation. It's worth spending a little more on high-quality bulbs, as their energy efficiency and long lifespan mean the investment will begin to pay for itself in just 1.5 years compared to fluorescent lamps and 3-4 years compared to LEDs. And in subsequent years, the savings are even greater!

If you want to learn more about this topic or analyze what replacing your lighting will look like – contact usWe present the most reliable solutions at a very competitive price. We prepare the lighting design and prepare all necessary electrical equipment for installation. 